Observer nTAP 10/100/1000 Copper (Discontinued)

Copy gigabit traffic from a full-duplex copper link for a copper monitoring device
Imagen

Features

  • Copies gigabit traffic from a full-duplex copper link for a copper monitoring device
  • Auto-negotiates to also support 10 Mb and Fast Ethernet networks
  • Connects to the full-duplex link under test and an analyzer equipped with a dual-receive capture card

Install Observer nTAPs on 10 Mb, 100 Mb, or 1 Gb copper links for quick, anytime access to network traffic. Depending on your network, choose 10/100 or 10/100/1000 copper nTAPs to send perfect copies of critical traffic to network analyzers, remote monitoring appliances, forensics tools, and similar dual-receive devices. For further flexibility an Observer Copper-to-Optical Conversion nTAP is available.

nTAPs are passive, full-duplex devices, offering complete visibility to monitoring devices regardless of traffic level. They work with the leading management tools for quick and easy deployment. nTAPs are transparent for monitoring critical links, and provide continuous network data flow even if power fails. nTAPs are scalable, modularized, space efficient, and economical.

Which nTAP do I need? Tap vs Span

Place a 10/100/1000 Copper nTAP between two devices of interest on a 100 Mbps or 1000 Mbps copper link. Then attach a copper monitoring device to the nTAP. To successfully analyze the full-duplex link, the monitoring device must be equipped with a dual-receive capture card.

Dimensions

Depth 7.66 in / 19.46 cm
Width (faceplate front) 5.85 in / 14.86 cm
Width (back) 4.55 in / 11.56 cm
Height (faceplate) 1.10 in / 2.79 cm

Power Requirements

Specification Measurement/Value
AC Input 90 V to 264 V, 47 Hz to 63 Hz
Operational Voltage 5 V (+10% to -5%, < 100 mV ripple)
Operational Current Typical: <= 1.8 amps  Max: <= 2.8 amps
Power Dissipation Typical: 8 W  Max: 14 W

Supported Media

Interface Media
Link A/Link B (Link under test) RJ45
Copper Analyzer Interface RJ45

Environmental Requirements

Specification Operational Range  Storage Range
Temperature range 32° to 120°F / 0° to 55 °C  32° - 167°F / 0° - 75°C
Humidity 35-85% (non-condensating)

Regulatory Compliance

Specification Certification
Emissions FCC Part 15 Class B
CE Mark EN61000-3-2, EN55024, EN55022A