Certifier 40G Selected the wrong limit (re-certification)
Knowledge Base - FAQ
My cable tests, with my Viavi 40G Certifier, were tested with the wrong limit selected. Is there a way this can be changed after the fact or do I have to retest the cables over again?
For cat 6A and below the 40G Certifier always tests and saves data out to 500mhz (Cat6A) so the cables can be re-certified to a different limit using the J-Reporter software. With the results open in J-Reporter, select the cable/cables to be changed by highlighting them and then right click and select Re-certification. You will get a pop up window of limits to chose from. Pick the correct limit and hit OK. The software will apply that limit to those selected cables.